Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Shoulder Elb ; 27(1): 88-107, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38147872

RESUMO

The aim of this systematic review was to collect evidence on the following 10 technical aspects of glenoid baseplate fixation in reverse total shoulder arthroplasty (rTSA): screw insertion angles; screw orientation; screw quantity; screw length; screw type; baseplate tilt; baseplate position; baseplate version and rotation; baseplate design; and anatomical safe zones. Five literature libraries were searched for eligible clinical, cadaver, biomechanical, virtual planning, and finite element analysis studies. Studies including patients >16 years old in which at least one of the ten abovementioned technical aspects was assessed were suitable for analysis. We excluded studies of patients with: glenoid bone loss; bony increased offset-reversed shoulder arthroplasty; rTSA with bone grafts; and augmented baseplates. Quality assessment was performed for each included study. Sixty-two studies were included, of which 41 were experimental studies (13 cadaver, 10 virtual planning, 11 biomechanical, and 7 finite element studies) and 21 were clinical studies (12 retrospective cohorts and 9 case-control studies). Overall, the quality of included studies was moderate or high. The majority of studies agreed upon the use of a divergent screw fixation pattern, fixation with four screws (to reduce micromotions), and inferior positioning in neutral or anteversion. A general consensus was not reached on the other technical aspects. Most surgical aspects of baseplate fixation can be decided without affecting fixation strength. There is not a single strategy that provides the best outcome. Therefore, guidelines should cover multiple surgical options that can achieve adequate baseplate fixation.

2.
Bone Joint J ; 105-B(7): 775-782, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37394959

RESUMO

Aims: The aims of this study were to determine if an increasing serum cobalt (Co) and/or chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip disability and Osteoarthritis Outcome Score (HOOS) in patients who received the Articular Surface Replacement (ASR) hip resurfacing arthroplasty (HRA), and to evaluate the ten-year revision rate and show if sex, inclination angle, and Co level influenced the revision rate. Methods: A total of 62 patients with an ASR-HRA were included and monitored yearly postoperatively. At follow-up, serum Co and Cr levels were measured and the HHS and the HOOS were scored. In addition, preoperative patient and implant variables and the need for revision surgery were recorded. We used a linear mixed model to relate the serum Co and Cr levels to different patient-reported outcome measures (PROMs). For the survival analyses we used the Kaplan-Meier and Cox regression model. Results: We found that an increase of one part per billion (ppb) in serum Co and Cr levels correlated significantly with worsening of the HHS in the following year. This significant correlation was also true for the HOOS-Pain and HOOS-quality of life sub scores. The overall ten-year survival rate in our cohort was 65% (95% confidence interval (CI) 52.5 to 77.6). Cox regression analysis showed a significant hazard ratio (HR) of 1.08 (95% CI 1.01 to 1.15; p = 0.028) for serum Co level. No significance was found with sex or inclination angle. Conclusion: This study shows that increasing serum Co and Cr levels measured in patients with an ASR-HRA are predictive for deterioration in HHS and HOOS subscales in the following year. Increasing serum Co and Cr should forewarn both surgeon and patient that there is a heightened risk of failure. Continued and regular review of patients with an ASR-HRA implant by measurement of serum Co/Cr levels and PROMs remains essential.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Cromo , Cobalto , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Qualidade de Vida , Falha de Prótese , Desenho de Prótese , Reoperação , Medidas de Resultados Relatados pelo Paciente , Seguimentos
3.
J Shoulder Elbow Surg ; 32(12): 2508-2518, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37327989

RESUMO

BACKGROUND: Although reverse total shoulder arthroplasty (RTSA) is considered a viable treatment strategy for proximal humeral fractures, there is an ongoing discussion of how its revision rate compares with indications performed in the elective setting. First, this study evaluated whether RTSA for fractures conveyed a higher revision rate than RTSA for degenerative conditions (osteoarthritis, rotator cuff arthropathy, rotator cuff tear, or rheumatoid arthritis). Second, this study assessed whether there was a difference in patient-reported outcomes between these 2 groups following primary replacement. Finally, the results of conventional stem designs were compared with those of fracture-specific designs within the fracture group. MATERIALS AND METHODS: This was a retrospective comparative cohort study with registry data from the Netherlands, generated prospectively between 2014 and 2020. Patients (aged ≥ 18 years) were included if they underwent primary RTSA for a fracture (<4 weeks after trauma), osteoarthritis, rotator cuff arthropathy, rotator cuff tear, or rheumatoid arthritis, with follow-up until first revision, death, or the end of the study period. The primary outcome was the revision rate. The secondary outcomes were the Oxford Shoulder Score, EuroQol 5 Dimensions (EQ-5D) score, numerical rating scale score (pain at rest and during activity), recommendation score, and scores assessing change in daily functioning and change in pain. RESULTS: This study included 8753 patients in the degenerative condition group (mean age, 74.3 ± 7.2 years) and 2104 patients in the fracture group (mean age, 74.3 ± 7.8 years). RTSA performed for fractures showed an early steep decline in survivorship: Adjusted for time, age, sex, and arthroplasty brand, the revision risk after 1 year was significantly higher in these patients than in those with degenerative conditions (hazard ratio [HR], 2.50; 95% confidence interval, 1.66-3.77). Over time, the HR steadily decreased, with an HR of 0.98 at year 6. Apart from the recommendation score (which was slightly better within the fracture group), there were no clinically relevant differences in the patient-reported outcome measures after 12 months. Patients who received conventional stems (n = 1137) did not have a higher likelihood of undergoing a revision procedure than those who received fracture-specific stems (n = 675) (HR, 1.70; 95% confidence interval, 0.91-3.17). CONCLUSION: Patients undergoing primary RTSA for fractures have a substantially higher likelihood of undergoing revision within the first year following the procedure than patients with degenerative conditions preoperatively. Although RTSA is regarded as a reliable and safe treatment option for fractures, surgeons should inform patients accordingly and incorporate this information in decision making when opting for head replacement surgery. There were no differences in patient-reported outcomes between the 2 groups and no differences in revision rates between conventional and fracture-specific stem designs.


Assuntos
Artrite Reumatoide , Artroplastia do Ombro , Osteoartrite , Lesões do Manguito Rotador , Fraturas do Ombro , Articulação do Ombro , Humanos , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/efeitos adversos , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/etiologia , Estudos Retrospectivos , Estudos de Coortes , Resultado do Tratamento , Osteoartrite/cirurgia , Osteoartrite/etiologia , Fraturas do Ombro/cirurgia , Fraturas do Ombro/etiologia , Artrite Reumatoide/cirurgia , Dor/etiologia , Articulação do Ombro/cirurgia , Amplitude de Movimento Articular
4.
Arch Orthop Trauma Surg ; 143(6): 3119-3128, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35840714

RESUMO

INTRODUCTION: It is unclear if the collar and cuff treatment improve alignment in displaced surgical neck fractures of the proximal humerus. Therefore, this study evaluated if the neckshaft angle and extent of displacement would improve between trauma and onset of radiographically visible callus in non-operatively treated surgical neck fractures (Boileau type A, B, C). MATERIALS AND METHODS: A consecutive series of patients (≥ 18 years old) were retrospectively evaluated from a level 1 trauma center in Australia (inclusion period: 2016-2020) and a level 2 trauma center in the Netherlands (inclusion period: 2004 to 2018). Patients were included if they sustained a Boileau-type fracture and underwent initial non-operative treatment. The first radiograph had to be obtained within 24 h after the initial injury and the follow-up radiograph(s) 1 week after trauma and before the start of radiographically visible callus. On each radiograph, the maximal medial gap (MMG), maximal lateral gap (MLG), and neck-shaft angle (NSA) were measured. Linear mixed modelling was performed to evaluate if these measurements would improve over time. RESULTS: Sixty-seven patients were included: 25 type A, 11 type B, and 31 type C fractures. The mean age (range) was 68 years (24-93), and the mean number (range) of follow-up radiographs per patient was 1 (1-4). Linear mixed modelling on both MMG and MLG revealed no improvement during follow-up among the three groups. Mean NSA of type A fractures improved significantly from 161° at trauma to 152° at last follow-up (p-value = 0.004). CONCLUSIONS: Apart from humeral head angulation improvement in type A, there is no increase nor reduction in displacement among the three fracture patterns. Therefore, it is advised that surgical decision-making should be performed immediately after trauma. LEVEL OF CLINICAL EVIDENCE: Level IV, retrospective case series.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Humanos , Idoso , Adolescente , Estudos Retrospectivos , Fraturas do Ombro/cirurgia , Fixação Interna de Fraturas , Radiografia , Cabeça do Úmero , Resultado do Tratamento , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia
5.
Clin Shoulder Elb ; 25(4): 304-310, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36330721

RESUMO

BACKGROUND: The Boileau classification distinguishes three surgical neck fracture patterns: types A, B, and C. However, the reproducibility of this classification on plain radiographs is unclear. Therefore, we questioned what the interobserver agreement and accuracy of displaced surgical neck fracture patterns is categorized according to the modified Boileau classification. Does the reliability to recognize these fracture patterns differ between orthopedic residents and attending surgeons? METHODS: This interobserver study consisted of a randomly retrieved series of 30 plain radiographs representing clinical practice in a level 1 and a level 2 trauma center. Radiographs were included from patients (≥18 years) who sustained an isolated displaced surgical neck fracture if they were taken ≤1 week after initial injury. A ground truth was established by consensus among three senior orthopedic surgeons. All images were assessed by 17 orthopedic residents and 17 attending orthopedic trauma surgeons. RESULTS: Agreement for the modified Boileau classification was fair (κ=0.37; 95% confidence interval [CI], 0.36-0.38) with an accuracy of 62% (95% CI, 57%-66%). Comparison of interobserver variability between residents and attending surgeons revealed a significant but clinically irrelevant difference in favor of attending surgeons (0.34 vs. 0.39, respectively, Δ κ=0.05, 95% CI, 0.02-0.07). CONCLUSIONS: The modified Boileau classification yields a low interobserver agreement with an unsatisfactory accuracy in a panel of orthopedic residents and attending surgeons. This supports the hypothesis that surgical neck fractures are challenging to categorize and that this classification should not be used to determine prognosis if only plain radiographs are available.

6.
Clin Orthop Relat Res ; 480(1): 150-159, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34427569

RESUMO

BACKGROUND: Reliably recognizing the overall pattern and specific characteristics of proximal humerus fractures may aid in surgical decision-making. With conventional onscreen imaging modalities, there is considerable and undesired interobserver variability, even when observers receive training in the application of the classification systems used. It is unclear whether three-dimensional (3D) models, which now can be fabricated with desktop printers at relatively little cost, can decrease interobserver variability in fracture classification. QUESTIONS/PURPOSES: Do 3D-printed handheld models of proximal humerus fractures improve agreement among residents and attending surgeons regarding (1) specific fracture characteristics and (2) patterns according to the Neer and Hertel classification systems? METHODS: Plain radiographs, as well as two-dimensional (2D) and 3D CT images, were collected from 20 patients (aged 18 years or older) who sustained a three-part or four-part proximal humerus fracture treated at a Level I trauma center between 2015 and 2019. The included images were chosen to comprise images from patients whose fractures were considered as difficult-to-classify, displaced fractures. Consequently, the images were assessed for eight fracture characteristics and categorized according to the Neer and Hertel classifications by four orthopaedic residents and four attending orthopaedic surgeons during two separate sessions. In the first session, the assessment was performed with conventional onscreen imaging (radiographs and 2D and 3D CT images). In the second session, 3D-printed handheld models were used for assessment, while onscreen imaging was also available. Although proximal humerus classifications such as the Neer classification have, in the past, been shown to have low interobserver reliability, we theorized that by receiving direct tactile and visual feedback from 3D-printed handheld fracture models, clinicians would be able to recognize the complex 3D aspects of classification systems reliably. Interobserver agreement was determined with the multirater Fleiss kappa and scored according to the categorical rating by Landis and Koch. To determine whether there was a difference between the two sessions, we calculated the delta (difference in the) kappa value with 95% confidence intervals and a two-tailed p value. Post hoc power analysis revealed that with the current sample size, a delta kappa value of 0.40 could be detected with 80% power at alpha = 0.05. RESULTS: Using 3D-printed models in addition to conventional imaging did not improve interobserver agreement of the following fracture characteristics: more than 2 mm medial hinge displacement, more than 8 mm metaphyseal extension, surgical neck fracture, anatomic neck fracture, displacement of the humeral head, more than 10 mm lesser tuberosity displacement, and more than 10 mm greater tuberosity displacement. Agreement regarding the presence of a humeral head-splitting fracture was improved but only to a level that was insufficient for clinical or scientific use (fair to substantial, delta kappa = 0.33 [95% CI 0.02 to 0.64]). Assessing 3D-printed handheld models adjunct to onscreen conventional imaging did not improve the interobserver agreement for pattern recognition according to Neer (delta kappa = 0.02 [95% CI -0.11 to 0.07]) and Hertel (delta kappa = 0.01 [95% CI -0.11 to 0.08]). There were no differences between residents and attending surgeons in terms of whether 3D models helped them classify the fractures, but there were few differences to identify fracture characteristics. However, none of the identified differences improved to almost perfect agreement (kappa value above 0.80), so even those few differences are unlikely to be clinically useful. CONCLUSION: Using 3D-printed handheld fracture models in addition to conventional onscreen imaging of three-part and four-part proximal humerus fractures does not improve agreement among residents and attending surgeons on specific fracture characteristics and patterns. Therefore, we do not recommend that clinicians expend the time and costs needed to create these models if the goal is to classify or describe patients' fracture characteristics or pattern, since doing so is unlikely to improve clinicians' abilities to select treatment or estimate prognosis. LEVEL OF EVIDENCE: Level III, diagnostic study.


Assuntos
Fraturas do Ombro , Tomografia Computadorizada por Raios X , Humanos , Cabeça do Úmero , Variações Dependentes do Observador , Impressão Tridimensional , Reprodutibilidade dos Testes , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia
7.
JSES Int ; 5(4): 754-764, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34223426

RESUMO

BACKGROUND: Lesser tuberosity fractures are relatively rare, with an incidence of 0.46 per 100,000 persons per year. This systematic review was performed to address patient-reported outcomes (PROMs), shoulder function, and complications after lesser tuberosity fractures in pediatric and adult patients, as well as patients with an associated posterior shoulder dislocation. Within these groups, identical outcomes were evaluated for nonoperative, surgical, acute and delayed treatment. METHOD: A comprehensive search was carried out in multiple databases. Articles were included if patients sustained a lesser tuberosity fracture without a concomitant proximal humerus fracture. There were no restrictions on age, type of treatment, fragment displacement, time to presentation, or associated injuries. RESULTS: One thousand six hundred forty-four records were screened for eligibility of which 71 studies were included (n = 172). Surgical treatment was provided to 50 of 62 (81%) pediatric patients, 49 of 66 (74%) adults, and 34 of 44 (77%) patients with an associated posterior shoulder dislocation. In the pediatric group, the mean of PROMs was 94 (range 70-100) and among adults 89 (range 85-100). In the posterior shoulder dislocation group, 89% did not regain full range of motion and the complication rate was 17%. In pediatric patients, surgery was associated with fewer complications (P = .021) compared to nonoperative treatment. CONCLUSION: Pediatric patients have excellent outcomes after lesser tuberosity fractures and respond well to surgical treatment. Adults have acceptable outcomes but patients with an associated posterior shoulder dislocation have impaired range of shoulder movement and are more likely to develop complications.

9.
J Foot Ankle Surg ; 60(4): 712-717, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33789807

RESUMO

The incidence of geriatric ankle fractures is rising and the potential for complications is high in this population. Little is known about factors associated with increased postoperative complications after surgical fixation of ankle fractures in older-age patients. The purpose of this retrospective cohort study was to assess the epidemiology and risk factors for complications after surgically treated ankle fractures in geriatric patients. All patients who were 65 years or older and had a surgically treated ankle fracture were included. Pilon fractures, patients who were initially treated conservatively or who had less than 1 month of follow-up were excluded. Postoperative complications, demographic-, fracture- and surgical data of 282 patients were recorded from two level 2 trauma centers between 2012 and 2017. A total of 87 (30.9%) patients developed a complication, of which wound related complications were most frequently reported. Superficial and deep wound infections were observed in 27 (9.6%) and 18 (6.4%) patients, respectively. Multivariate regression analysis demonstrated increased age to be an independent predictive variable for the occurrence of postoperative complications (odds ratio 1.04; 95% confidence interval 1.00-1.09), while cast immobilization for more than 2 weeks was a protective factor for the development of wound related complications (odds ratio 0.34; 95% confidence interval 0.17-0.66). In conclusion, the incidence of postoperative complications among geriatric patients after surgical treatment of ankle fractures is high and patients should be informed accordingly.


Assuntos
Fraturas do Tornozelo , Fraturas da Tíbia , Idoso , Fixação Interna de Fraturas , Humanos , Complicações Pós-Operatórias , Estudos Retrospectivos , Infecção da Ferida Cirúrgica , Resultado do Tratamento
10.
Knee Surg Sports Traumatol Arthrosc ; 28(11): 3551-3560, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32979080

RESUMO

PURPOSE: Evaluation of survival of meniscal allograft transplantation (MAT) and postoperative patient-reported outcome (PRO), and their association with prior interventions of the knee. METHODS: A prospective consecutive study of 109 consecutive patients who had an arthroscopic meniscal allograft transplantation (MAT) between 1999 and 2017 by a single surgeon. Patients were assessed with KOOS scores, preoperative and after a minimal follow-up of 2 years. Furthermore, two anchor questions (whether expectations were met and overall satisfaction, on a five-point Likert scale) were asked. Additionally, prior interventions to MAT were evaluated. RESULTS: Prior to MAT, patients had undergone an average of 2.8 (range 1-14) of surgical procedures of the knee. Overall, mean allograft survival was 16.1 years (95% CI 14.8-17.5 years). Higher age at surgery was associated with lower MAT survival: hazard ratio for MAT failure was 1.19 per year increase (95% CI 1.04 to 1.36, p = 0.009). At 4.5 years (IQR, 2-9) of follow-up, all KOOS score were still improved compared to baseline. Age below 35 years, simultaneous anterior cruciate ligament reconstruction and number of knee surgeries before MAT were associated with lower KOOS scores. Overall patient expectations and overall satisfaction after MAT were not associated with preoperative patient characteristics nor with the number or kind of preoperative interventions. CONCLUSION: Meniscal allograft transplantation has a good overall survival with a clinically relevant improvement. Both meniscal allograft survival and PRO were associated with age. PRO was lower in patients younger than 35 years at time of MAT and meniscal allograft survival was worse in patients older than 50 years. PRO was associated with preoperative patient characteristics and number of surgical procedures prior to MAT. All patients reported improved postoperative satisfaction and met expectations after MAT, both independent of the preoperative history of knee interventions. LEVEL OF EVIDENCE: Level III. Trial registration Medical ethical review board (METC) number: 17-104 (7 August 2017). Dutch Trial Register (NTR) number: NTR6630 (4 July 2017).


Assuntos
Artroscopia/métodos , Sobrevivência de Enxerto , Meniscos Tibiais/transplante , Medidas de Resultados Relatados pelo Paciente , Lesões do Menisco Tibial/cirurgia , Adulto , Aloenxertos , Reconstrução do Ligamento Cruzado Anterior/métodos , Feminino , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Masculino , Menisco/cirurgia , Pessoa de Meia-Idade , Países Baixos , Satisfação do Paciente , Estudos Prospectivos , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...